UTR Sensor
No items found.

UTR Sensor

Autonics UTR Series adalah Ultrasonic Sensor berbentuk cylindrical yang dirancang untuk mendeteksi dan mengukur berbagai jenis material serta permukaan secara akurat. Dengan fitur temperature compensation, IO-Link, dan housing stainless steel 316L, UTR Series cocok untuk berbagai aplikasi otomasi industri.

  • Detect and measure various material and surface types with ultrasonic sensing
  • Sensing distance (by mount diameter)
    • M18 Model : 30 to 350 mm / 65 to 600 mm / 120 to 1,300 mm
    • M30 Model : 600 to 8,000 mm
  • Temperature compensation (auto/manual) and detection width conversion function for high accuracy
  • 316L stainless steel body for high corrosion resistance
  • 360º ring type indicator to check operation status from any direction
  • Digital output (Push-Pull) support
  • IO-Link models, Simultaneous digital and analog output models available
  • Configure settings and monitor status with ultrasonic sensor programming units (UT-P)
  • Dedicated software provided (atDistance)
  • Protection structure: IP66, IP67, IP68, IP69K (may vary by model)
Add To Cart
Data Sheet

Autonics UTR Series merupakan Cylindrical Ultrasonic Sensor yang menggunakan teknologi gelombang ultrasonik untuk mendeteksi keberadaan objek dan mengukur jarak secara presisi, tanpa terpengaruh oleh warna, bentuk, maupun transparansi material. Sensor ini dapat digunakan untuk berbagai aplikasi seperti presence detection, pengukuran level cairan, material padat, dan powder.

Dengan pilihan housing M18 dan M30, UTR Series menawarkan rentang sensing distance hingga 8 meter sesuai model yang digunakan. Sensor ini dilengkapi fitur temperature compensation otomatis/manual dan detection width conversion untuk menjaga akurasi pengukuran pada berbagai kondisi lingkungan.

UTR Series tersedia dengan berbagai opsi output seperti Push-Pull digital output, analog output, serta model dengan dukungan IO-Link untuk konfigurasi dan monitoring yang lebih mudah. Pengaturan parameter dan pemantauan status sensor juga dapat dilakukan menggunakan programming unit UT-P atau software khusus atDistance.

Dengan desain industri yang kuat menggunakan material stainless steel 316L, indikator operasi ring 360°, serta perlindungan hingga IP69K (tergantung model), Autonics UTR Series Ultrasonic Sensor menjadi solusi ideal untuk aplikasi otomasi industri yang membutuhkan deteksi stabil, fleksibel, dan akurat.

Technical Specifications — Autonics UTR Series Ultrasonic Sensor
General
Model UTRCM18-350 UTRCM18-600 UTRCM18-1300 UTRCM30-8M
Sensing Distance 30 to 350 mm 65 to 600 mm 120 to 1300 mm 600 to 8000 mm
Blind Zone 0 to 27 mm 0 to 59 mm 0 to 115 mm 0 to 590 mm
Foreground Suppression 30 to 90 mm 65 to 195 mm 120 to 360 mm 600 to 1800 mm
Max. Setting Zone 350 mm 600 mm 1300 mm 8000 mm
Transducer Frequency 305 kHz 305 kHz 200 kHz 80 kHz
Switching Frequency ≥ 25 Hz ≥ 12.5 Hz ≥ 10 Hz ≥ 3 Hz
Response Time ≤ 32 ms ≤ 64 ms ≤ 100 ms ≤ 300 ms
Hysteresis 3 mm 5 mm 20 mm 100 mm
Standard Sensing Target Aluminum 200 × 200 mm Aluminum 200 × 200 mm Aluminum 200 × 200 mm Aluminum 500 × 500 mm
Resolution ≥ 0.069 mm ≥ 0.069 mm ≥ 0.175 mm ≥ 0.180 mm
Accuracy ±1% F.S.
Repeat Accuracy ±0.15% F.S.
Weight (Packaged) ≈30 g (≈85 g) ≈30 g (≈85 g) ≈32 g (≈90 g) ≈210 g (≈330 g)
Electrical
Power Supply 12–30 VDC (Ripple P-P ≤10%)
Current Consumption ≤40 mA ≤40 mA ≤45 mA ≤80 mA
Digital Output Push-Pull
Load Voltage ≤30 V
Load Current ≤100 mA
Residual Voltage ≤3 V
Analog Output
Analog Output Current Output: DC 4–20 mA / Voltage Output: DC 0–10 V
Load Resistance Current Output: 12–20 VDC ≤100 Ω / 20–30 VDC ≤500 Ω
Voltage Output: 12–30 VDC ≥100 kΩ
Protection & Electrical Safety
Protection Circuit Surge protection circuit, output short over-current protection circuit, reverse polarity protection
Insulation Resistance ≥50 MΩ (500 VDC Megger)
Dielectric Strength Between charging part and case: 1,000 VAC, 50/60 Hz for 1 minute
Environmental
Vibration 1.5 mm double amplitude at frequency of 10 to 55 Hz in each X, Y, Z direction for 2 hours
Shock 500 m/s² (≈50 G) in each X, Y, Z direction for 3 times
Ambient Temperature -25 to 70 ℃
Storage: -40 to 85 ℃ (No freezing or condensation)
Protection Rating IP66, IP67, IP69K IP66, IP67, IP69K IP66, IP67, IP69K IP66, IP67
Mechanical
Connection Connector Models
Connector Specification M12 5-pin Plug Connector
Case Material SUS316L Stainless Steel
Body Material PC
Transducer Material Polyurethane Foam, Epoxy Resin with Glass
Certification
Certification CE, IO-Link

01) If a sensing target is detected over the blind zone and below the foreground suppression range, the distance value is displayed as the foreground suppression value.
02) Parameters can be configured using the sensor settings or the dedicated atDistance software.
03) Accuracy specified at ambient temperature 25 ℃ (temperature characteristic: ±0.1% F.S./℃).

* Specifications are subject to change without prior notice. Please refer to the official Autonics datasheet for the latest technical information.